Gledhill ElectraMate 2000 9kW Parts & Spares Guide

Guide to Gledhill Electramate 2000 9kW Parts: Understanding Your Heating System

If you own a Gledhill Electramate 2000 9kW heating system, it's essential to understand its various parts and their functions to ensure optimal performance and troubleshoot any issues effectively. Below is a comprehensive guide to help you navigate through the components:

  • RAVK Mixing Valve Head (Early Model) GT098: The mixing valve head regulates the temperature of the water flowing through your heating system, ensuring a comfortable and consistent output.

  • Mixing Valve/CA Valve Washers XC008: These washers maintain the integrity of the mixing valve, preventing leaks and ensuring proper functioning.

  • Y Strainer XB314: The Y strainer filters out debris and impurities from the water supply, protecting other components such as pumps and valves from damage.

  • Replacement Pipework ZB014: This pipework is designed to replace worn-out or damaged sections, ensuring seamless water flow throughout the system.

  • Plastic F + E Tank XB343: The F + E (Feed and Expansion) tank maintains the correct water levels in the heating system, accommodating expansion and preventing overpressure.

  • Flow Regulator GT086: This component regulates the flow of water, optimizing energy efficiency and preventing excessive pressure within the system.

  • Electronic Noise Filter XB307: The noise filter minimizes electrical interference, ensuring smooth operation and preventing disruptions to electronic components.

  • Ballvalve FT207 and Ball Float FT429: These work in tandem to control the water level in the F + E tank, maintaining the correct balance and preventing overflow.

  • Pump Valve And Housing GT045: The pump valve and housing regulate the flow of water through the pump, ensuring efficient circulation throughout the system.

  • Immersion Washer FT407: This washer seals the immersion heater element, preventing leaks and ensuring safe operation.

  • Brass Housing Superseded By GT045 (GT049): This housing provides support and protection for the pump valve, enhancing its durability and longevity.

  • 24 Litre Expansion Vessel Was XG192 (XG216): The expansion vessel accommodates fluctuations in water volume due to heating, preventing damage to the system from excessive pressure.

  • Modification Kit (170 Model) MIP116 and Modification Kit (270 Model) MIP115: These kits include various components to upgrade and optimize specific models of the Electramate 2000, improving performance and reliability.

  • Switch Overheat Thermostat XB347: This thermostat monitors the temperature of the system, shutting it down if it exceeds safe levels to prevent damage or overheating.

  • Switch Heating Element XB342: This switch controls the operation of the heating element, allowing you to adjust the temperature settings as needed.

  • Summer/Winter Switch GT034: This switch allows you to toggle between summer and winter modes, adjusting the system's operation based on seasonal requirements.

  • Aav/Avv Pipework MIP029: This pipework facilitates the installation of air admittance valves, preventing airlocks and ensuring smooth water flow.

  • Mixing Valve XC005: This valve mixes hot and cold water to achieve the desired temperature output, enhancing comfort and efficiency.

  • 90 Degree Angle Ballvalve XB398: This ball valve provides precise control over water flow direction, allowing for efficient plumbing configurations.

  • Tundish XB392: The tundish serves as a safety device, providing a visual indication of any discharge from safety valves or overflows.

  • Pressure Reducing Valve XB391: This valve regulates water pressure, protecting the system from damage caused by excessive pressure from the mains supply.

  • CA Backflow Prevention Valve XB390: The backflow prevention valve ensures that water flows in one direction only, preventing contamination of the mains water supply.

  • 5 Amp Fuse XB382, 25 Amp Fuse XB364, Ac30 Fuse Base XB363: These fuses and fuse base protect the electrical components of the system from overload and short circuits.

  • Programmable Room Stat XB365: This thermostat allows you to program heating schedules based on your preferences, optimizing energy usage and comfort.

  • 22mm Pump Valves XB121: These valves control the flow of water through the pump, facilitating efficient circulation within the system.

  • Grundfos 15/50 Pump XB004 (Replacement Pump) XB1016: The Grundfos pump is a reliable and efficient component responsible for circulating water throughout the heating system.

  • Expansion Relief Valve GT195: This valve releases excess pressure from the expansion vessel, safeguarding the system from damage due to overpressure.

  • Primary System Pressure Gauge GT179: The pressure gauge provides a visual indication of the system's pressure, allowing for easy monitoring and adjustment.

  • Appliance Control PCB (Version Hex) GT155: The PCB (Printed Circuit Board) controls the operation of various components within the heating system, ensuring proper functionality.

  • Hot Water Sensor GT153 and Store Sensor GT147: These sensors monitor water temperature in different parts of the system, allowing for precise control and efficient operation.

  • Overheat Thermostat GT064: This thermostat acts as a safety feature, shutting down the system if temperatures exceed safe limits to prevent damage or injury.

  • Anti Vacuum Valve GT056: The anti-vacuum valve prevents the formation of a vacuum within the system, ensuring smooth water flow and preventing damage to components.

  • Plate Heat Exchanger GT017: The heat exchanger transfers heat between different water circuits within the system, maximizing energy efficiency and hot water production.

  • Automatic Air Vent GT015: This vent automatically releases trapped air from the system, ensuring optimal performance and preventing airlocks.

Understanding these components and their functions will empower you to effectively maintain and troubleshoot your Gledhill Electramate 2000 9kW heating system, ensuring reliable performance and longevity. If you encounter any issues beyond your expertise, don't hesitate to seek professional assistance to ensure the safety and efficiency of your system.